News

How to maintain the capsule filling machine

Author: ComeFrom: Date:2020/2/29 15:37:05 Hits:70

Cleaning parts

1, the normal working hours of the machine, to be regularly in contact with the drug, when the replacement of drug batches or longer time to stop, but also to clean up.

Add lubricating oil

2, the machine work under the surface of the transmission should always be appropriate to add the amount of lubricating oil (grease), in order to reduce the wear of moving parts.

Check oil quantity

3, the main drive reducer monthly to check 1 times the amount of oil, lack of timely refueling, every six months to replace 1 lubricating oil; rotary dividing box each running 3000h to replace the 1 lubricating oil, according to the experience of using 90# oil.

Safety clutch

4, safety clutch is protective in overload, the normal load when the clutch should not slip, but because of long time use may also occur when the slipping phenomenon, slipping phenomenon during normal use, can be circular clutch nut to achieve, to ensure the normal operation of the machine and can play a protective role the purpose of.

Vacuum separator

Vacuum separator 5, vacuum system in filling hard capsule mainly to the capsule on the suction module and separating the cap and body function, if not isolated cap and body capsule, subsequent filling will not be carried out. The turntable of the machine runs 1 stations every time. The machine spindle rotates 1 weeks. The vacuum separator is moving up and down 1 times under the action of the cam. If the capsule cap, the separation is not smooth, should check the vacuum gap between the planar separator and the upper plane of the lower module, clearance of the vacuum system of vacuum degree is not up to the separation of cap and body required vacuum (about 0.05MPa), the gap is too small and easy to produce the module against deformation. When the vacuum separator position need to be adjusted, the rotation shaft of the main motor by the handle, the vacuum separator rises to the highest position, loosen the machine under the table adjusting rod at both ends of the lock nut (a left-handed nut, a nut, a regulating dextrorotation) vacuum rod adjusts the height of the separator, and then lock nut with the rotation of the handle, a shaft of the main motor test until the appropriate date. Vacuum degree in the machine operation panel on the vacuum table read out, vacuum can be properly opened when the vacuum degree control valve, vacuum can be passed down the small or close the vacuum valve. The filter of the vacuum system should be regularly open to clean up the dirt to ensure that the vacuum system has enough vacuum.

Driving chain

6, the chain of transmission should be checked weekly for 1 times, and add the appropriate amount of grease, it is necessary to re tighten. When the chain is too loose to be re tightened, move the tensioner adjustment, but will not open the chain cannot get off the chain sprocket, so as not to disrupt the order of motion of the mechanism, prevention mechanism of motion interference.

Next:Type capsule filling machine